In Kenya mains electricity is about 240 V at 50 Hz, supplied by KPLC from sources such as geothermal and hydro stations.
At constant temperature the current through a conductor is directly proportional to the potential difference across it:
V = IR
A graph of V against I for an ohmic conductor is a straight line through the origin; its gradient is the resistance. A filament lamp is non-ohmic because its resistance rises as it heats.
Worked example 1: A resistor carries 0.5 A when connected to 6 V. R = 6 / 0.5 = 12 ohms.
Resistance increases with length, decreases with cross-sectional area, depends on the material, and generally rises with temperature. R = (resistivity x length) / area.
Worked example 2: A 6 ohm and 3 ohm resistor are in parallel across 12 V.
The e.m.f. (E) of a cell is the total energy supplied per coulomb. E = V + Ir, where r is the internal resistance, so the terminal voltage drops when current is drawn.
Worked example 3: A 2 kW kettle is used 15 minutes daily for 30 days. Energy = 2 x 0.25 x 30 = 15 kWh. At KES 25/kWh, cost = KES 375.
A fuse protects against overcurrent. Choose a fuse rating just above normal current: I = P/V. For a 460 W appliance at 230 V, I = 2 A, so use a 3 A fuse. Earth wires, circuit breakers and insulated cables prevent shock and fire.
Test yourself with 5 question(s) drawn from this topic - answer online and mark instantly.